價格
¥4,998.00
型號
進(jìn)口鋰電池供電電磁流量計
品牌
RETZ
所在地
上海市 徐匯區(qū)
更新時間
2023-08-11 17:27:33
瀏覽次數(shù)
次
其他推薦產(chǎn)品
首頁| 關(guān)于我們| 聯(lián)系我們| 友情鏈接| 廣告服務(wù)| 會員服務(wù)| 付款方式| 意見反饋| 法律聲明| 服務(wù)條款
:RETZ/我們一直致力于流體控制和測控領(lǐng)域的持續(xù)創(chuàng)新,始于2005……進(jìn)口鋰電池供電電磁流量計原理及用途Principle and purpose
1.電池供電電磁流量計由傳感器和轉(zhuǎn)換器兩部分構(gòu)成。它是基于法拉第電磁感應(yīng)定律工作的,用來測量電導(dǎo)率大于5μS/cm導(dǎo)電液體的體積流量,是一種測量導(dǎo)電介質(zhì)體積流量的感應(yīng)式儀表。除可測量一般導(dǎo)電液體的體積流量外,還可用于測量強(qiáng)酸強(qiáng)堿等強(qiáng)腐蝕液體和泥漿、礦漿、紙漿等均勻的液固兩相懸浮液體的體積流量retz The battery powered electromagnetic flowmeter consists of a sensor and a converter. It isd on Faraday's law of electromagnetic induction and is used to
measure electrical conductivity greater than 5 μ The volume flow rate of S/cm
conductive liquid is an inductive instrument for measuring the volume flow rate
of conductive media. In addition to measuring the volume flow rate of general
conductive liquids, it can also be used to measure the volume flow rate of
strong corrosive liquids such as strong acids and alkalis, and homogeneous
liquid-solid two-phase suspension liquids such as mud, pulp, and pulp
2.基本原理(如圖所示)基于法拉第電磁感應(yīng)定律:E=K*B*D*V,其中E是感應(yīng)電動勢;K是儀表常數(shù);B是磁感應(yīng)強(qiáng)度;D是測量管直徑;V是平均流速 The basic principle (as shown in the figure) isd on Faraday's law of electromagnetic
induction: E=K * B * D * V, where E is the induced electromotive force; K is
the meter constant; B is the magnetic induction strength; D is the diameter of
the measuring tube; V is the average flow rate
(1)只能測量導(dǎo)電介質(zhì) Only conductive media can be measured
電導(dǎo)率限制條件6≥1-5uS/cm(水>20uS/cm)(低電導(dǎo)率>0.05uS/cm使用儀表) Conductivity limit condition 6 ≥ 1-5uS/cm (water>20uS/cm) (low conductivity>0.05uS/cm using dedicated instruments)原理及用途.jpg
不能測量非導(dǎo)電介質(zhì),如氣體,油類,如介質(zhì)含有大量氣體,產(chǎn)生測量嚴(yán)重波動 Unable to measure non-conductive media such as gases and oils, such as media containing a large amount of gas, resulting in severe fluctuations in measurement
(2)必須存在磁場 Magnetic field must be present
勵磁電流流經(jīng)測量管上下勵磁線圈產(chǎn)生磁場。勵磁線圈斷路,流量計不工作,勵磁電流穩(wěn)定性直接影響儀表測量 The excitation current flows through the upper and lower excitation coils of the measuring tube to generate a magnetic field. The excitation coil is open circuit, the flowmeter does not work, and the stability of the excitation current directly affects the instrument measurement
測量管必須為非導(dǎo)磁材料,保證磁場穿過導(dǎo)管(測量管應(yīng)采用不銹鋼材質(zhì)) The measuring tube must be made of non magnetic conductive material to ensure that the magnetic field passes through the tube (the measuring tube should be made of stainless steel)
(3)實際測量值為流體流速 The actual measured value is the fluid flow rate
電磁流量計實際測量介質(zhì)的流速(它是速度式流量計) Electromagnetic flowmeter actually measures the flow rate of the medium (it is a velocity type flowmeter)
進(jìn)口鋰電池供電電磁流量計技術(shù)參數(shù) Technical parameter
公稱通徑(mm)
(特殊規(guī)格可定制)
管道式:DN10~DN3000
插入式:DN200~DN3000
流動方向:
正,反,凈流量
量程比:
150:1
重復(fù)性誤差:
測量值的±0.1%
精度等級:
管道式:0.5級,1.0級
被測介質(zhì)溫度:
普通橡膠襯里:-20~+60℃
高溫橡膠襯里:-20~+90℃
聚四氟乙稀襯里:-30~+100℃
高溫型四氟襯里:-20~+180℃
額定工作壓力:
(高壓可定制)
DN6-DN80:≤1.6MPa
DN100-DN250:≤1.0MPa
DN300-DN1200:≤0.6MPa
流速范圍:
0.1-15m/s
電導(dǎo)率范圍:
被測流體電導(dǎo)率≥5μs/cm
電流輸出:
負(fù)載電阻
0~10mA:0~1.5kΩ
4~20mA:0~750 kΩ
數(shù)字頻率輸出:
輸出頻率上限可在1~5000HZ內(nèi)設(shè)定帶光電隔離的晶體管集電極開路雙向輸出。外接電源≤35V導(dǎo)通時集電極*大電流為250mA
供電電源:
AC220V、DC24V或3.6V電池
要求直管段長度
上游≥5DN,下游≥2DN
連接方式:
流量計與配管之間均采用法蘭連接,法蘭連接尺寸應(yīng)符合GB11988的規(guī)定
防爆等級:
mdIIBT4
防護(hù)等級:
IP65,特殊訂制*高可達(dá)IP68
環(huán)境溫度:
-25~+60℃
相對溫度:
5%~95%
消耗功率:
小于20W
富林克致力于作為流體控制*,負(fù)責(zé)地區(qū)RETZ產(chǎn)品的營銷管理和服務(wù),從而創(chuàng)造價值的企業(yè),RETZ以“堅持更好的品質(zhì)”為根本,以“持續(xù)實現(xiàn)具有創(chuàng)造性、高品質(zhì)產(chǎn)品和服務(wù)的企業(yè)價值,為當(dāng)今社會的繁榮作出貢獻(xiàn)”為企業(yè)理念